RFM water-cooled capacitors are the compensation capacitors for medium-frequency induction furnaces. They correct power factor and form the resonant tank with the induction coil.
RFM capacitor ratings and outline — factory sheet, all listed models| Model | UN (kV) | QN (kvar) | FN (kHz) | CN (µF) | IN (A) | Groups | L (mm) | B (mm) | H (mm) | I (mm) | II (mm) | b (mm) | Weight (kg) |
|---|
| RFM0.75-500-2.5S | 0.75 | 500 | 2.5 | 56.59 | 666.7 | 4 | 303 | 120 | 250 | 105 | 87 | 55 | 14.0 |
| RFM0.75-500-10S | 0.75 | 500 | 10.0 | 14.15 | 666.7 | 4 | 303 | 120 | 195 | 105 | 87 | 55 | 12.0 |
| RFM0.75-640-4S | 0.75 | 640 | 4.0 | 45.27 | 853.3 | 4 | 303 | 142 | 250 | 105 | 87 | 55 | 16.5 |
| RFM0.75-640-8S | 0.75 | 640 | 8.0 | 22.64 | 853.3 | 4 | 303 | 120 | 225 | 105 | 87 | 55 | 16.0 |
| RFM0.75-640-10S | 0.75 | 640 | 10.0 | 18.11 | 853.3 | 4 | 303 | 120 | 210 | 105 | 87 | 55 | 12.5 |
| RFM0.75-1000-0.5S | 0.75 | 1000 | 0.5 | 565.9 | 1333 | 8 | 440 | 165 | 445 | 85 | 82 | 75 | 49.0 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 31.0 |
| RFM20.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 350 | 80 | 75 | 75 | 29.5 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 32.0 |
| RFM0.75-1000-2.5S | 0.75 | 1000 | 2.5 | 113.2 | 1333 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 22.0 |
| RFM1.0-1000-0.5S | 1.0 | 1000 | 0.5 | 318.3 | 1000 | 6 | 440 | 165 | 385 | 125 | 87 | 75 | 40.0 |
| RFM1.0-1000-1S | 1.0 | 1000 | 1.0 | 159.2 | 1000 | 6 | 336 | 142 | 350 | 80 | 75 | 60 | 25.0 |
| RFM1.0-1000-2S | 1.0 | 1000 | 2.0 | 79.58 | 1000 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.0-1000-2.5S | 1.0 | 1000 | 2.5 | 63.66 | 1000 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 21.5 |
| RFM1.2-750-0.5S | 1.2 | 750 | 0.5 | 165.8 | 625 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 30.5 |
| RFM1.2-1000-0.5S | 1.2 | 1000 | 0.5 | 221.0 | 833.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1000-0.7S | 1.2 | 1000 | 0.7 | 157.9 | 833.3 | 6 | 336 | 165 | 335 | 80 | 75 | 75 | 27.5 |
| RFM1.2-1200-0.7S | 1.2 | 1200 | 0.7 | 189.5 | 1000 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 31.0 |
| RFM1.2-1250-0.65S | 1.2 | 1250 | 0.65 | 212.5 | 1042 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1400-0.7S | 1.2 | 1400 | 0.7 | 221.0 | 1167 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1500-0.5S | 1.2 | 1500 | 0.5 | 331.6 | 1250 | 6 | 440 | 165 | 495 | 125 | 87 | 75 | 48.0 |
| RFM1.2-2000-0.5S | 1.2 | 2000 | 0.5 | 442.1 | 1667 | 8 | 440 | 205 | 435 | 85 | 82 | 95 | 56.0 |
| RFM1.2-2000-0.65S | 1.2 | 2000 | 0.65 | 340.1 | 1667 | 8 | 440 | 165 | 495 | 85 | 82 | 75 | 48.0 |
| RFM1.4-1000-0.5S | 1.4 | 1000 | 0.5 | 162.4 | 714.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.4-1000-1S | 1.4 | 1000 | 1.0 | 81.2 | 714.3 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.4-2000-0.5S | 1.4 | 2000 | 0.5 | 324.8 | 1429 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 54.0 |
| RFM1.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 460 | 125 | 87 | 95 | 54.5 |
| RFM21.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1500-0.25S | 1.7 | 1500 | 0.25 | 330.4 | 882.4 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 71.0 |
| RFM1.7-2000-0.5S | 1.7 | 2000 | 0.52 | 220.3 | 1176 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1000-0.15S | 1.7 | 1000 | 0.15 | 367.1 | 588.2 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 72.0 |
Capacitor service conditions — factory sheet| Item | Value |
|---|
| Installation altitude | Not above 1000 m |
| Site | No severe shock, corrosive gas, steam or explosive dust |
| Cooling-water inlet | Not above 30°C / 86°F |
| Cooling-water flow | At least 4 L/min below 1000 kvar; at least 6 L/min at 1000 kvar and above |
| Overvoltage | 1.1 × UN for 4 hours |
| Continuous current | Not above 1.35 × IN |
| Catalog standards | JB/T 7110-93 and IEC 60110-1 (1998) |
| Suffix S | Water-cooled. No S suffix on the air-cooled construction shown on the same sheet |
| Model code | RFM, voltage kV, kvar, frequency kHz, S = water-cooled |
American standards| US standard | Applies to |
|---|
| IEC 60110-1 | Power capacitors for induction heating — the catalog rating standard |
| IEEE 18 | US shunt-capacitor standard buyers ask to see beside IEC 60110-1 |
| IEEE 519 | Harmonic duty seen by the capacitor bank |
| ASTM B187 | Copper bus bar in the capacitor rack |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
Air-cooled RFM capacitors are used where a water circuit is not wanted on the capacitor itself. They serve the same tank-circuit duty on small and medium furnaces.
RFM capacitor ratings and outline — factory sheet, all listed models| Model | UN (kV) | QN (kvar) | FN (kHz) | CN (µF) | IN (A) | Groups | L (mm) | B (mm) | H (mm) | I (mm) | II (mm) | b (mm) | Weight (kg) |
|---|
| RFM0.75-500-2.5S | 0.75 | 500 | 2.5 | 56.59 | 666.7 | 4 | 303 | 120 | 250 | 105 | 87 | 55 | 14.0 |
| RFM0.75-500-10S | 0.75 | 500 | 10.0 | 14.15 | 666.7 | 4 | 303 | 120 | 195 | 105 | 87 | 55 | 12.0 |
| RFM0.75-640-4S | 0.75 | 640 | 4.0 | 45.27 | 853.3 | 4 | 303 | 142 | 250 | 105 | 87 | 55 | 16.5 |
| RFM0.75-640-8S | 0.75 | 640 | 8.0 | 22.64 | 853.3 | 4 | 303 | 120 | 225 | 105 | 87 | 55 | 16.0 |
| RFM0.75-640-10S | 0.75 | 640 | 10.0 | 18.11 | 853.3 | 4 | 303 | 120 | 210 | 105 | 87 | 55 | 12.5 |
| RFM0.75-1000-0.5S | 0.75 | 1000 | 0.5 | 565.9 | 1333 | 8 | 440 | 165 | 445 | 85 | 82 | 75 | 49.0 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 31.0 |
| RFM20.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 350 | 80 | 75 | 75 | 29.5 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 32.0 |
| RFM0.75-1000-2.5S | 0.75 | 1000 | 2.5 | 113.2 | 1333 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 22.0 |
| RFM1.0-1000-0.5S | 1.0 | 1000 | 0.5 | 318.3 | 1000 | 6 | 440 | 165 | 385 | 125 | 87 | 75 | 40.0 |
| RFM1.0-1000-1S | 1.0 | 1000 | 1.0 | 159.2 | 1000 | 6 | 336 | 142 | 350 | 80 | 75 | 60 | 25.0 |
| RFM1.0-1000-2S | 1.0 | 1000 | 2.0 | 79.58 | 1000 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.0-1000-2.5S | 1.0 | 1000 | 2.5 | 63.66 | 1000 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 21.5 |
| RFM1.2-750-0.5S | 1.2 | 750 | 0.5 | 165.8 | 625 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 30.5 |
| RFM1.2-1000-0.5S | 1.2 | 1000 | 0.5 | 221.0 | 833.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1000-0.7S | 1.2 | 1000 | 0.7 | 157.9 | 833.3 | 6 | 336 | 165 | 335 | 80 | 75 | 75 | 27.5 |
| RFM1.2-1200-0.7S | 1.2 | 1200 | 0.7 | 189.5 | 1000 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 31.0 |
| RFM1.2-1250-0.65S | 1.2 | 1250 | 0.65 | 212.5 | 1042 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1400-0.7S | 1.2 | 1400 | 0.7 | 221.0 | 1167 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1500-0.5S | 1.2 | 1500 | 0.5 | 331.6 | 1250 | 6 | 440 | 165 | 495 | 125 | 87 | 75 | 48.0 |
| RFM1.2-2000-0.5S | 1.2 | 2000 | 0.5 | 442.1 | 1667 | 8 | 440 | 205 | 435 | 85 | 82 | 95 | 56.0 |
| RFM1.2-2000-0.65S | 1.2 | 2000 | 0.65 | 340.1 | 1667 | 8 | 440 | 165 | 495 | 85 | 82 | 75 | 48.0 |
| RFM1.4-1000-0.5S | 1.4 | 1000 | 0.5 | 162.4 | 714.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.4-1000-1S | 1.4 | 1000 | 1.0 | 81.2 | 714.3 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.4-2000-0.5S | 1.4 | 2000 | 0.5 | 324.8 | 1429 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 54.0 |
| RFM1.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 460 | 125 | 87 | 95 | 54.5 |
| RFM21.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1500-0.25S | 1.7 | 1500 | 0.25 | 330.4 | 882.4 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 71.0 |
| RFM1.7-2000-0.5S | 1.7 | 2000 | 0.52 | 220.3 | 1176 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1000-0.15S | 1.7 | 1000 | 0.15 | 367.1 | 588.2 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 72.0 |
Capacitor service conditions — factory sheet| Item | Value |
|---|
| Installation altitude | Not above 1000 m |
| Site | No severe shock, corrosive gas, steam or explosive dust |
| Cooling-water inlet | Not above 30°C / 86°F |
| Cooling-water flow | At least 4 L/min below 1000 kvar; at least 6 L/min at 1000 kvar and above |
| Overvoltage | 1.1 × UN for 4 hours |
| Continuous current | Not above 1.35 × IN |
| Catalog standards | JB/T 7110-93 and IEC 60110-1 (1998) |
| Suffix S | Water-cooled. No S suffix on the air-cooled construction shown on the same sheet |
| Model code | RFM, voltage kV, kvar, frequency kHz, S = water-cooled |
American standards| US standard | Applies to |
|---|
| IEC 60110-1 | Power capacitors for induction heating — the catalog rating standard |
| IEEE 18 | US shunt-capacitor standard buyers ask to see beside IEC 60110-1 |
| IEEE 519 | Harmonic duty seen by the capacitor bank |
| ASTM B187 | Copper bus bar in the capacitor rack |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
The capacitor bank is the assembled rack of medium-frequency capacitors, busbar and water manifold next to the furnace. A large single-unit kvar rating keeps the pit small and the high-current loop short.
RFM capacitor ratings and outline — factory sheet, all listed models| Model | UN (kV) | QN (kvar) | FN (kHz) | CN (µF) | IN (A) | Groups | L (mm) | B (mm) | H (mm) | I (mm) | II (mm) | b (mm) | Weight (kg) |
|---|
| RFM0.75-500-2.5S | 0.75 | 500 | 2.5 | 56.59 | 666.7 | 4 | 303 | 120 | 250 | 105 | 87 | 55 | 14.0 |
| RFM0.75-500-10S | 0.75 | 500 | 10.0 | 14.15 | 666.7 | 4 | 303 | 120 | 195 | 105 | 87 | 55 | 12.0 |
| RFM0.75-640-4S | 0.75 | 640 | 4.0 | 45.27 | 853.3 | 4 | 303 | 142 | 250 | 105 | 87 | 55 | 16.5 |
| RFM0.75-640-8S | 0.75 | 640 | 8.0 | 22.64 | 853.3 | 4 | 303 | 120 | 225 | 105 | 87 | 55 | 16.0 |
| RFM0.75-640-10S | 0.75 | 640 | 10.0 | 18.11 | 853.3 | 4 | 303 | 120 | 210 | 105 | 87 | 55 | 12.5 |
| RFM0.75-1000-0.5S | 0.75 | 1000 | 0.5 | 565.9 | 1333 | 8 | 440 | 165 | 445 | 85 | 82 | 75 | 49.0 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 31.0 |
| RFM20.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 350 | 80 | 75 | 75 | 29.5 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 32.0 |
| RFM0.75-1000-2.5S | 0.75 | 1000 | 2.5 | 113.2 | 1333 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 22.0 |
| RFM1.0-1000-0.5S | 1.0 | 1000 | 0.5 | 318.3 | 1000 | 6 | 440 | 165 | 385 | 125 | 87 | 75 | 40.0 |
| RFM1.0-1000-1S | 1.0 | 1000 | 1.0 | 159.2 | 1000 | 6 | 336 | 142 | 350 | 80 | 75 | 60 | 25.0 |
| RFM1.0-1000-2S | 1.0 | 1000 | 2.0 | 79.58 | 1000 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.0-1000-2.5S | 1.0 | 1000 | 2.5 | 63.66 | 1000 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 21.5 |
| RFM1.2-750-0.5S | 1.2 | 750 | 0.5 | 165.8 | 625 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 30.5 |
| RFM1.2-1000-0.5S | 1.2 | 1000 | 0.5 | 221.0 | 833.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1000-0.7S | 1.2 | 1000 | 0.7 | 157.9 | 833.3 | 6 | 336 | 165 | 335 | 80 | 75 | 75 | 27.5 |
| RFM1.2-1200-0.7S | 1.2 | 1200 | 0.7 | 189.5 | 1000 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 31.0 |
| RFM1.2-1250-0.65S | 1.2 | 1250 | 0.65 | 212.5 | 1042 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1400-0.7S | 1.2 | 1400 | 0.7 | 221.0 | 1167 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1500-0.5S | 1.2 | 1500 | 0.5 | 331.6 | 1250 | 6 | 440 | 165 | 495 | 125 | 87 | 75 | 48.0 |
| RFM1.2-2000-0.5S | 1.2 | 2000 | 0.5 | 442.1 | 1667 | 8 | 440 | 205 | 435 | 85 | 82 | 95 | 56.0 |
| RFM1.2-2000-0.65S | 1.2 | 2000 | 0.65 | 340.1 | 1667 | 8 | 440 | 165 | 495 | 85 | 82 | 75 | 48.0 |
| RFM1.4-1000-0.5S | 1.4 | 1000 | 0.5 | 162.4 | 714.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.4-1000-1S | 1.4 | 1000 | 1.0 | 81.2 | 714.3 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.4-2000-0.5S | 1.4 | 2000 | 0.5 | 324.8 | 1429 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 54.0 |
| RFM1.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 460 | 125 | 87 | 95 | 54.5 |
| RFM21.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1500-0.25S | 1.7 | 1500 | 0.25 | 330.4 | 882.4 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 71.0 |
| RFM1.7-2000-0.5S | 1.7 | 2000 | 0.52 | 220.3 | 1176 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1000-0.15S | 1.7 | 1000 | 0.15 | 367.1 | 588.2 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 72.0 |
Capacitor service conditions — factory sheet| Item | Value |
|---|
| Installation altitude | Not above 1000 m |
| Site | No severe shock, corrosive gas, steam or explosive dust |
| Cooling-water inlet | Not above 30°C / 86°F |
| Cooling-water flow | At least 4 L/min below 1000 kvar; at least 6 L/min at 1000 kvar and above |
| Overvoltage | 1.1 × UN for 4 hours |
| Continuous current | Not above 1.35 × IN |
| Catalog standards | JB/T 7110-93 and IEC 60110-1 (1998) |
| Suffix S | Water-cooled. No S suffix on the air-cooled construction shown on the same sheet |
| Model code | RFM, voltage kV, kvar, frequency kHz, S = water-cooled |
American standards| US standard | Applies to |
|---|
| IEC 60110-1 | Power capacitors for induction heating — the catalog rating standard |
| IEEE 18 | US shunt-capacitor standard buyers ask to see beside IEC 60110-1 |
| IEEE 519 | Harmonic duty seen by the capacitor bank |
| ASTM B187 | Copper bus bar in the capacitor rack |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.