A water cooling station is the packaged pump and tower set for one furnace or for a pair of furnaces. It is the practical way to ship cooling equipment with a complete melting system.
Technical Data
| Model | Water 37–32°C (m³/h) | Water 40–32°C (m³/h) | Water 55–35°C (m³/h) | Fan power (kW) | Air flow (m³/s) | Spray pump (kW) | Spray water (m³/h) | Inlet/outlet | Working pressure (MPa) | Weight (kg) | Size L×W×H (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FBT-100 | 100 | 65 | 45 | 1.1 | 33 | 0.75 | 22 | 80×4 | 0.35 | 3250 | 2410×3000×4620 |
| FBT-125 | 125 | 81 | 56 | 2.2 | 42 | 1.5 | 26 | 80×4 | 0.35 | 3545 | 2410×5220×4620 |
| FBT-150 | 150 | 95 | 67 | 3 | 42 | 1.5 | 26 | 80×4 | 0.35 | 3785 | 2410×5220×4620 |
| FBT-175 | 175 | 109 | 78 | 3 | 50 | 1.5 | 44 | 80×8 | 0.35 | 4300 | 2410×3000×4620 |
| FBT-200 | 200 | 130 | 90 | 4.4 | 63 | 2.2 | 44 | 80×8 | 0.35 | 4750 | 2410×3550×4620 |
| FBT-250 | 250 | 162 | 112 | 4.4 | 56 | 2.2 | 52 | 80×8 | 0.5 | 5300 | 2410×3550×4620 |
| FBT-300 | 300 | 190 | 132 | 4.4 | 82 | 2.2 | 52 | 100×12 | 0.5 | 6200 | 2410×3550×4620 |
| FBT-350 | 350 | 221 | 154 | 6 | 82 | 3 | 88 | 100×12 | 0.5 | 7000 | 2410×3550×4620 |
| FBT-400 | 400 | 260 | 180 | 6 | 126 | 4 | 88 | 100×8 | 0.6 | 8100 | 2410×2510×4620 |
| FBT-450 | 450 | 291 | 200 | 8 | 126 | 5.5 | 132 | 100×8 | 0.6 | 8700 | 2410×2510×4620 |
| FBT-500 | 500 | 320 | 227 | 12 | 126 | 5.5 | 132 | 100×8 | 0.6 | 9350 | 2140×2510×4620 |
| FBT-60-II | 60 | 39 | 27 | 12 | 25 | 7.5 | 22 | 80×4 | 0.3 | 2800 | 2410×2510×4620 |
| FBT-70-II | 70 | 45 | 31 | 16 | 25 | 4×2 | 22 | 80×4 | 0.35 | 2950 | 2410×2510×4620 |
| FBT-80-II | 80 | 52 | 36 | 16 | 33 | 5.5×2 | 26 | 100×4 | 0.35 | 3250 | 2410×2510×4620 |
| FBT-100-II | 100 | 55 | 45 | 24 | 33 | 5.5×2 | 26 | 100×4 | 0.35 | 3420 | 2410×2510×4620 |
| FBT-125-II | 125 | 81 | 58 | 24 | 42 | 7.5×2 | 26 | 100×4 | 0.35 | 3780 | 2410×2510×4620 |
| FBT-150-II | 150 | 96 | 67 | 24 | 42 | 4×4 | 44 | 80×8 | 0.35 | 4150 | 2410×2510×4620 |
| FBI-175-II | 175 | 109 | 78 | 32 | 48 | 4×4 | 44 | 80×8 | 0.4 | 4350 | 2410×2910×4620 |
| FBI-200-II | 200 | 130 | 90 | 32 | 48 | 5.5×4 | 44 | 80×8 | 0.5 | 4950 | 2410×2910×4620 |
| Item | Catalog statement |
|---|---|
| Process water | Soft water in a closed coil, no contact with outside air, no scaling in the furnace circuit |
| Open pond | Not used on the process-water side |
| Spray section | Collects spray water; the coil stays clean |
| Fan drive | Low-power motor with a gear reducer |
| Cold climate | Antifreeze heating, cooling and heating in one tower |
| Energy statement on the sheet | About 30% less than comparable domestic towers, small fan and high water flow |
| US standard | Applies to |
|---|---|
| CTI STD-201 | Cooling Technology Institute thermal performance for US towers |
| NEMA MG 1 | Fan and pump motors |
| NFPA 70 (NEC) | Tower and pump electrical supply |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
| Model | Water 37–32°C (m³/h) | Water 40–32°C (m³/h) | Water 55–35°C (m³/h) | Fan power (kW) | Air flow (m³/s) | Spray pump (kW) | Spray water (m³/h) | Inlet/outlet | Working pressure (MPa) | Weight (kg) | Size L×W×H (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HL-20 | 20 | 13 | 9 | 4×2 | 4.5 | 3.7 | 5.5 | 65×2 | 0.25 | 750 | 2050×1280×2000 |
| HL-30 | 30 | 19 | 13 | 5.5×2 | 7 | 2.2×2 | 8 | 80×2 | 0.25 | 1050 | 2510×1280×2100 |
| HL-40 | 40 | 26 | 18 | 5.5×2 | 7 | 2.2×2 | 10 | 80×2 | 0.3 | 1150 | 2510×1280×2200 |
| HL-50 | 50 | 33 | 23 | 4×3 | 11 | 3.7×2 | 13 | 80×2 | 0.3 | 1300 | 2510×1280×2550 |
| HL-60 | 60 | 39 | 27 | 5.5×3 | 13 | 2.2×4 | 15 | 100×2 | 0.3 | 1450 | 2510×1530×2650 |
| HL-70 | 70 | 45 | 31 | 4×4 | 15 | 2.2×4 | 17 | 100×2 | 0.35 | 1850 | 2510×1530×2750 |
| HL-80 | 80 | 52 | 36 | 5.5×4 | 17 | 3.7×4 | 20 | 100×2 | 0.35 | 2050 | 2510×1530×2850 |
| HL-100 | 100 | 65 | 45 | 5.5×4 | 25 | 3.7×4 | 30 | 80×4 | 0.35 | 2850 | 3000×1780×2850 |
| HL-125 | 125 | 81 | 56 | 5.5×6 | 30 | 3.7×6 | 40 | 100×4 | 0.35 | 3250 | 3000×1780×2950 |
| HL-150 | 150 | 95 | 67 | 5.5×6 | 40 | 3.7×6 | 50 | 80×8 | 0.35 | 3750 | 3000×2130×3350 |
| HL-175 | 175 | 109 | 78 | 5.5×6 | 45 | 3.7 | 50 | 80×8 | 0.35 | 4095 | 3940×2210×3450 |
| HL-200 | 200 | 130 | 90 | 3×2 | 50 | 3.7 | 60 | 80×8 | 0.35 | 4500 | 3940×2210×3550 |
| HL-250 | 250 | 162 | 112 | 3×2 | 60 | 2.2×2 | 80 | 100×8 | 0.5 | 6120 | 4300×2500×3350 |
| HL-300 | 300 | 190 | 132 | 4×2 | 80 | 2.2×2 | 100 | 80×16 | 0.5 | 6840 | 3000×5000×3350 |
| HL-350 | 350 | 221 | 154 | 4×2 | 100 | 2.2×2 | 100 | 80×16 | 0.5 | 7600 | 3940×5200×3450 |
| HL-400 | 400 | 260 | 180 | 5.5×2 | 120 | 3.7×2 | 120 | 80×16 | 0.6 | 8500 | 3940×5200×3550 |
| HL-450 | 450 | 291 | 200 | 5.5×2 | 120 | 3.7×2 | 120 | 100×16 | 0.6 | 9450 | 4300×5200×3550 |
| HL-500 | 500 | 320 | 227 | 7.5×2 | 120 | 3.7×2 | 120 | 100×16 | 0.6 | 9900 | 4300×5700×3550 |
| HL-550 | 550 | 350 | 250 | 7.5×2 | 130 | 3.7×2 | 130 | 100×16 | 0.6 | 11500 | 4300×5700×3750 |
| Item | Catalog statement |
|---|---|
| Winter | Fan can stay off; cooling is by gravity flow |
| Drift loss | About 0.5%, with a drift eliminator |
| Water make-up | About 1% |
| Basin | Built onto the tower, so a separate cold-water pit is not required |
| Wear parts | Make-up water, fan and motor |
| US standard | Applies to |
|---|---|
| CTI STD-201 | Cooling Technology Institute thermal performance for US towers |
| NEMA MG 1 | Fan and pump motors |
| NFPA 70 (NEC) | Tower and pump electrical supply |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
Key features
- Matched to furnace power and to coil plus capacitor loss
- Closed-circuit or crossflow tower
- Pump redundancy where the foundry asks for it
- Indoor or outdoor layout
Construction
- Skid or pit pumps, tower, headers and the electrical interlock to the KGPS supply.
Working principle
The station removes the heat that the power supply, the coil and the capacitors produce, and it does it at the flow the furnace drawing requires.
Applications
Steel, cast iron, stainless steel, copper, aluminum, aluminum alloy, brass and other non-ferrous metals.
Complete system integration
This equipment sits in the same line as the power supply, the capacitor bank, the induction coil, the magnetic yoke, the furnace body and the cooling system. A quotation can cover one item or the full line.
Customization
Capacity, voltage, frequency, dimensions and connection layout can be made to the furnace design. Send the drawing or the duty data below.
Catalog sheets


Questions before a quotation
Can the rating be customized?
Yes. Capacity, voltage, frequency, tube size and connection layout follow the furnace drawing and the metal.
What do you need for a quotation?
Furnace capacity, metal, melting temperature, melting rate, working hours, input voltage, frequency if known, tilting method and cooling-water conditions. A drawing helps.
Do you supply a single machine or the complete system?
Both. A spare coil, yoke, capacitor or cooling tower can be quoted alone. A new foundry line is quoted as a complete system.
Which metals can be melted?
Steel, cast iron, stainless steel, copper, aluminum, aluminum alloy, brass and other non-ferrous metals. The lining and the frequency follow the alloy.
Will you confirm the catalog numbers before manufacture?
Yes. The sheets on this page are the factory catalog for selection. The quotation states the rating that will be built.